  • Jimmy Fellegy created an article,

    FAQ: Why doesn't my RTH(Room Temp and Humidity) or MS(Multi Sensor) not reading?

    If you notice a zone with a current temperature of 0, chances are that the SmartNode has lost communication with the zone sensor.  Start with the following troubleshooting steps: Ensure that a cab...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Jimmy Fellegy created an article,

    FAQ: Field Installation Best Practices

    When starting a new 75F installation, being prepared is key.  The following are items that will help to increase the speed and efficiency of the process: Ensure you have 75F supplied wire and adap...

    • Edited
    • 2 followers
    • 0 comments
    • 1 vote
  • Jimmy Fellegy created an article,

    FAQ: Why wont my device pair to my CCU?

    Sometimes a device will have a hard time pairing with a CCU.  If that happens, try the following steps: Attempt to pair within 2 minutes of the device being placed in pairing mode Ensure no device...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Jimmy Fellegy created an article,

    Why are my SmartNode devices cycling power?

    Check incoming 24vac power at your Smart Node device.  Verify that there are no safeties or relays that could interrupt power to the Smart Node. If 23 volts and under convert to a larger VA power ...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Jimmy Fellegy created an article,

    FAQ: Prohibited locations for a CCU.

    Because the CCU uses Wi-Fi for internet connection and 900 MHz to communicate with field devices, it may be sensitive to noisy environments.  The tablets are also electronic devices that are not w...

    • Edited
    • 2 followers
    • 0 comments
    • 0 votes
  • Jimmy Fellegy created an article,

    FAQ: Why do I keep losing USB/CM connection?

    1.) Check incoming voltage at the 24v and C terminals at the CM for proper voltage. Be sure to continue to check through a call for fan, heating, cooling, etc and monitor for any temporary voltage ...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Jimmy Fellegy created an article,

    FAQ: Smart Node Pairing Best Practice

    It is best practice to redock the tablet after pairing every 5 SmartNode devices.  Allow all zones to connect and communicate with the CCU before proceeding to the next group.  This will also offer...

    • Edited