  • Scott Dudgeon created an article,

    FAQ: How can I change the Starting Pairing Address on my CCU?

    If your CCU is using 10xx for its pairing addresses, but you would like to change the addresses to 20xx, for example, you will need to delete all of the modules off before you can adjust that start...

    • Edited
    • 1 follower
    • 0 comments
    • 1 vote
  • Scott Dudgeon created an article,

    Heat Pump Unit - Smart Stat

    | How it Works 75F Smart Stat Heat Pump Profile allows for control of a heat pump.  Cooling Mode - If the zone requires cooling, then the reversing valve will move into the cooling position whether...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Scott Dudgeon created an article,

    Conventional Package Unit - Smart Stat

    2 Minute Read | How it Works The 75F Smart Stat Conventional Package Unit profile allows for control of a Conventional Package Unit.  Cooling Mode - Stage 1 cooling will engage as soon as your curr...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Scott Dudgeon created an article,

    Troubleshooting a Smart Stat

    | How to determine if a Smart Stat zone is in a dead condition and possible remedies Objective - Use Facilisight Heatmap zone condition indicators to determine if there is an issue with the data co...

    • Edited
    • 1 follower
    • 0 comments
    • 1 vote
  • Scott Dudgeon created an article,

    Troubleshooting a SmartNode

    3 Minute Read | How to determine if a SmartNode zone has stopped communicating and possible remedies Objective - Use Facilisight Heatmap Zone condition indicators to determine if there is a communi...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Scott Dudgeon created an article,

    User and Building Limits

    4 Minute Read | User and Building Limits Objective - Use the 75f tuning options to maximize comfort and economy, as well as monitor and alert you to possible issues. User Limits - A range of tempe...

    • Edited
    • 1 follower
    • 0 comments
    • 0 votes
  • Scott Dudgeon created an article,

    Deadband and Hysteresis

    2 Minute Read | Deadband and Hysteresis (Staged Equipment) Objective - Reduce short cycling to increase energy efficiency and increase the lifespan of the equipment.  Deadband- This is your desired...